Popular Articles
"Difference is too small" message (during calibration)
The reason for the message is that the change in analogue output from the scale base between zero calibration and the span calibration value is too small. The most likely reason is that the amount of weight placed on the scale for span calibration is ...
Changing display from kg to lb
Press and hold the F4 key down to get into the configuration menu (Dip switch 1 needs to be on, located under the small back cover on the rear of the indicator). Under the scale menu, scroll down using the F3 button until you find the menu "Allow ...
Screen shows ADC 2 error
This is usually a short circuit in the load cell cable, or an internal problem in the trimmer box. If the input signal from the load cells is shorted to the excitation voltage, then the scale will first read "Heavy Bag", then display the message "ADC ...
Printer connected to operator panel is not working
Press and hold the F4 button to enter the settings menu Press the “C” button (Next) to scroll to the RS-232 menu, and press “M-“ button to select Ensure that the Output is set for “Printer”. Use the F2 and F3 keys to change the selection Ensure baud ...
"Error Data Nil" message
The "Error Data Nil" message on the passenger panel means that power is applied, but no RS-485 data is received at the passenger panel. The centre two pins of the connector and cable are used for the communications. This issue can be associated with ...