How to put the operator panel into “Stream” mode

How to put the operator panel into “Stream” mode

1.       Hold the F4 button to enter the Setup menu

2.       Scroll down to RS-232 using F4 button

3.       Select using M- key

4.       With “Output” highlighted and using F2 key to scroll up or F3 key to scroll down, scroll to “Stream”

5.       Press * key to save

6.       Press “0” key to exit.



    • Related Articles

    • Setting a potential free contact

      The OP-960+ operator panel has two voltage free contacts, both of which are solid state relays. Wire the +pos from the PLC input to pin 3, and the return to Pin 4. Then set the function of the output 1. If the output is required to be closed above a ...
    • Black dot on the operator panel display

      The operator display has a black spot in the middle because the rear bracket has been fitted upside down, causing pressure to be transferred to the display.  If the bracket is turned the right way up the black dot will disappear.
    • Passenger panel shows "Err Char Bad"

      The data being sent from the operator panel is corrupted and the passenger panel is reporting the error as “Bad Char” or bad character received. There are no settings that could be wrong that will produce this error, and you will need to confirm if ...
    • "Bad addr" message on passenger panel

      The command from the operator panel has a standardised format that includes an address byte. The message on the passenger panel indicates that the format received is unexpected. The fault could be with the operator panel, load cell cable or the ...
    • Operator panel switches off soon after it's powered up