Black dot on the operator panel display

Black dot on the operator panel display

The operator display has a black spot in the middle because the rear bracket has been fitted upside down, causing pressure to be transferred to the display.  If the bracket is turned the right way up the black dot will disappear.



    • Related Articles

    • Operator display shows scale divisions of 0.01 instead of 0.1kg

      Remove the dip switch cover on the rear of the operator panel and return the position of Dip Switch 2 to “ON”.
    • Passenger panel shows "Err Char Bad"

      The data being sent from the operator panel is corrupted and the passenger panel is reporting the error as “Bad Char” or bad character received. There are no settings that could be wrong that will produce this error, and you will need to confirm if ...
    • "Bad addr" message on passenger panel

      The command from the operator panel has a standardised format that includes an address byte. The message on the passenger panel indicates that the format received is unexpected. The fault could be with the operator panel, load cell cable or the ...
    • Operator panel switches off soon after it's powered up

      This is because the remote power function is turned is on. Turn the unit on, press and hold the F4 button until you get into the set-up menu.  The indicator will remain on while you scroll to in the I/O menu and change Input One from "Remote Power" ...
    • Changing display from kg to lb

      Press and hold the F4 key down to get into the configuration menu (Dip switch 1 needs to be on, located under the small back cover on the rear of the indicator). Under the scale menu, scroll down using the F3 button until you find the menu "Allow ...