Operator display shows scale divisions of 0.01 instead of 0.1kg

Operator display shows scale divisions of 0.01 instead of 0.1kg

Remove the dip switch cover on the rear of the operator panel and return the position of Dip Switch 2 to “ON”.

    • Related Articles

    • Changing display from kg to lb

      Press and hold the F4 key down to get into the configuration menu (Dip switch 1 needs to be on, located under the small back cover on the rear of the indicator). Under the scale menu, scroll down using the F3 button until you find the menu "Allow ...
    • Changing display from kg to lb

      Press and hold the F4 key down to get into the configuration menu (Dip Switch 1, located under the small back cover on the rear of the indicator, has to be on). Under the scale menu, scroll down using the F3 button until you find the menu "Allow ...
    • Black dot on the operator panel display

      The operator display has a black spot in the middle because the rear bracket has been fitted upside down, causing pressure to be transferred to the display.  If the bracket is turned the right way up the black dot will disappear.
    • Scale shows incorrect weight

      Place a weight of around 40kg in the centre of the scale, note the reading, then move the weight to the four individual corners. Are the weight readings for the corners the same to within +/-0.2 kg? If yes, recalibrate the scales. If no, check the ...
    • Screen shows ADC 2 error

      This is usually a short circuit in the load cell cable, or an internal problem in the trimmer box. If the input signal from the load cells is shorted to the excitation voltage, then the scale will first read "Heavy Bag", then display the message "ADC ...